craig.cahillane@LIGO.ORG - posted 23:59, Monday 14 December 2015 (24220)
LHO O1 Uncertainty Budget
C. Cahillane

I have produced the total LHO uncertainty budget, now including Pcal sensing information at 1 kHz and 3 kHz. (Thanks Shivaraj!)

C01 means the kappas were left uncorrected in the uncertainty propagation.  C02 is the "perfect" calibration model, with kappas corrected.
C00 is the "nominal" model output by the front end, which has uncorrected kappas AND static frequency dependent systematics left in.

PDFs 1 and 2 each contain nine plots.  Plots 8 and 9 are the total magnitude and phase uncertainty in strain.  Plots 6 and 7 are the components that make up the uncertainty.  Plot 1 is the C00 response divided by either the C01 or C02 response to show the frequency dependent systematic errors that were corrected.

PDF 3 is the sensing measurements and fits.  (We have a nonlinear fit for the sensing function magnitude, which results in this dominating the uncertainty budget.)
PDF 4 is the actuation measurements and fits.

PDF 5 is the direct comparison of C01 and C02.  This basically shows the total effect correcting the kappas has on the response function.

LHO has a total uncertainty under 6% and 3.5 degrees  (See plots 8 and 9 from PDF 2)

For the LLO budget please see aLOG 23573