Following aLog 24208, all LHO ISI platforms were restarted. Most platforms deisolated nicely. But, HAM2 decidedly did not. New safe.snaps were captured for all platforms. This captured the FF paths being off at start up and GS13 being in low gain. Guardian was adjusted for HAM2 to desable the GS13 gain switching.
All snaps and isi/h1 guardians were committed to the svn.
The HAM ISIs were restarted to capture a code correction that clears saturation immediately upon request. The BSCs got this fix as well.
Also, since HAM2 & 3 do not tolerate GS13 gain switching via guardian, that feature, while available, is disabled. So, upon FE restart, the GS13s will be in low gain and the safe.snap SDF will be happy. But, under OBSERVE.snap, the GS13s in low gain will be red. These will need to be switched via the SEI Commands scripts.