Reports until 14:15, Wednesday 16 December 2015
H1 CDS
david.barker@LIGO.ORG - posted 14:15, Wednesday 16 December 2015 - last comment - 23:58, Wednesday 31 August 2016(24264)
Verbal Alarms code changed to log to the logging directory
the Verbal Alarms code was logging to the ops home directory. Prior to the move of this home directory (WP5658) I have modified the code to log to a new directory:

/ligo/logs/VerbalAlarms

We restarted the program at 14:04 and verified the log files are logging correctly.
Comments related to this report
jeffrey.kissel@LIGO.ORG - 14:45, Friday 26 August 2016 (29336)DetChar, GRD, ISC, SYS
These verbal log files actually live one level deeper, in
/ligo/logs/VerbalAlarms/Verbal_logs/

For the current month, the log files live in that folder. 
However, at the end of every month, they're moved into the dated subfolders, e.g.
/ligo/logs/VerbalAlarms/Verbal_logs/2016/7/

The text files themselves are named "verbal_m_dd_yyyy.txt".

Unfortunately, these are not committed to repo where these logs might be viewed off site. Maybe we;ll work on that.

Happy hunting!
thomas.shaffer@LIGO.ORG - 23:58, Wednesday 31 August 2016 (29428)

The Verbal logs are now copied over to the web-exported directory via a cronjob. Here, they live in /VerbalAlarms_logs/$(year)/$(month)/

The logs in /ligo/logs/VerbalAlarms/Verbal_logs/ will now always be in their month, even the curent ones.