david.barker@LIGO.ORG - posted 15:42, Sunday 27 December 2015 (24501)
daqd process on h1nds1 stopped, was restarted along with nds process

the daqd process on h1nds1 stopped running at 14:51 PST, log file details shown below. Looking back I see many of these "NDS failed" messages from the 12/24 21:14 evening restart (following the computer freeze up). I restarted the daqd process and then stopped and started the nds process. If we are having any problems getting archived data, we could try rebooting the machine.

[Sun Dec 27 14:51:07 2015] read(seq_num) from NDS failed; errno=0

[Sun Dec 27 14:51:07 2015] connection closed on fd=186

[Sun Dec 27 14:51:09 2015] read(seq_num) from NDS failed; errno=0

[Sun Dec 27 14:51:09 2015] connection on fd 144 closed

[Sun Dec 27 14:51:09 2015] connection closed on fd=226

[Sun Dec 27 14:51:09 2015] connection on fd 110 closed