Range wasn't looking so good either.
Excerpt from log:
09:40 POP_A_LF_OUTPUT looks ratty and he range has diminished down into low 70-high 60 land. Going to try switching to 45mHz blends at EX. uSei is kinda high bu winds are low.
09:42 Intention bit set to commissioning by SDF when changes to blend made
09:52 Switching blends to 45mHz at ETMX (X) seems to have decreased the amplitude in DHARD_PITCH_OUTMON. This seems to, maybe, have helped the range slightly.
10:02 Intention bit set to Observe. 76Mpc
Range is still up and down. The Inspiral Range Integrand looks a little less than nominal around the 12-13Hz area. The only correlating information I can see is that the Z axis in the 10-30 Hz anthropogenic bands are excessively higher than its X&Y counter-parts. Also, the 3-10Hz Z axis is elevated and uSei is above the 90th percentile mark. ?