Flurry of CW & TRANS Injection Verbal Alarms

Have received quite a few Injection Verbal Alarms over the last few minutes this morning for CW & TRANS (see attached snapshot).  Do operators need to do anything about this?  I talked with Tom E (L1 Operator) & they did not receive any alarms regarding these injections.

I brought up the CAL_INJ_CONTROL medm and looked at the Continuous Signal section of this window and have not seen anything change (and trended channels for CW and also don't see anything out of the ordinary).

Images attached to this report
Comments related to this report
darkhan.tuyenbayev@LIGO.ORG - 16:12, Wednesday 30 December 2015 (24572)

The CW and TRANS injection output channels don't seem to indicate presence of injections between 19:10:00 UTC and 19:50:00 UTC.

Images attached to this comment