Reports until 00:36, Tuesday 05 January 2016
H1 IOO (IOO, SUS)
cheryl.vorvick@LIGO.ORG - posted 00:36, Tuesday 05 January 2016 (24696)
alignment changes in yaw, for IM1, IM2, IM3, PRM and PR2, over 150 days (all of O1 plus a few days)

I looked into the recent change in H1 behavior, with H1:LSC-POP_A_LF_OUT dropping, and causing lock loss, and see alignment changes that could be contributing to this issue.

The shifting IMs in HAM2 cannot account for alignment changes in the 150 day trend, so there is something else at work here.

Changes in yaw over 150 days:

Changes in pitch, comparing PRM to PR2 (different chambers)

The change in PR2 yaw of +51urad is significantly larger than the changes in the PRM pitch and yaw, and PR2 pitch.

The changes in PR2 yaw may be a response to the cumulative effects of the smaller changes seen in IM1, IM2, and IM3.

Changes in IM pitch:

The change is IM3 yaw of -26urad is significant;y larger than the changes in pitch or yaw in IM1, IM2, and IM3.

Images attached to this report