After reviewing the trends I posted yesterday I determined that the ITMy and SR3 oplevs needed re-centering. This is now complete. The old and new pitch/yaw values for these oplevs are below.
Old (µrad) | New (µrad) | |||
Pitch | Yaw | Pitch | Yaw | |
ITMy | -11.1 | -12.1 | -0.2 | 0.0 |
SR3 | -13.8 | +5.2 | -0.2 | -0.1 |
This completes LHO WP #5676.