DARM noise earlier looks like another manifestation of RF 45
The noise reported earlier in log 24789 looks like another case of RF 45 problems that were not picked up by the monitor.

The first attachment is a spectrogram of DARM showing the burst of noise then a moving comb of lines. We've seen the RF 45 trouble manifest this way before - see log 23269.  Looking carefully at the monitor channel (second plot), one of the lines does appear there, though the burst of noise does not. POP_A_9Q does a good job of witnessing the problem (third plot).