Displaying report 1-1 of 1.
Reports until 10:53, Saturday 09 January 2016
H1 ISC (CDS)
jeffrey.kissel@LIGO.ORG - posted 10:53, Saturday 09 January 2016 - last comment - 12:24, Saturday 09 January 2016(24803)
Tried my favored placebo for RF45 Noise
J. Kissel, E. Merilh,

Though we know it *should* have no effect, and there has been no conclusive evidence that it does, while out of intent to change the PCALX line, we moved the set point of the EOM 45 MHz control servo (H1:LSC-MOD_RF45_AM_RFSET) breifly down to 22.4, then up to 23.4, and then back down to its nominal value of 23.2. As usual, it's unclear whether this has done anything. We're now back into observation mode, with the intent bit set. Though the hefty bit of large features has gone away, there remains a bit of broad-band bnoise from 30 to 200 [Hz], and an harmonic streak of glitches in the OMICRON triggers.
Images attached to this report
Comments related to this report
jeffrey.kissel@LIGO.ORG - 11:33, Saturday 09 January 2016 (24804)
And probably coincidentally, the noise subsided around 19:30 UTC. #facepalm
jeffrey.kissel@LIGO.ORG - 12:24, Saturday 09 January 2016 (24806)
And it's back, since 20:00:00 UTC. #doublefacepalm. I'll stop live tweeting the IFO's noise at this point, 'cause it's only getting me into trouble.
Displaying report 1-1 of 1.