cheryl.vorvick@LIGO.ORG - posted 20:28, Saturday 09 January 2016 - last comment - 23:36, Saturday 09 January 2016(24818)
Lock saved from decreasing POP_A_LF

Summary:

TMSY pitch and yaw alignment tweaked to increase POP_A_LF, saving the lock.

Details:

After JeffK and I saw that POP_A_LF was dropping, I looked at the H1 alignment over the 27 hour lock, and focused of PR3, ETMX, and TMSX.

After looking at the trends, I proposed the idea to JeffK that we might be able to save the lock by aligning TMS, and he suggested TMSY, based on previous work by Kiwamu.

When I compared TMSX and TMSY alignments over the 27 hour lock, I found that TMSY alignment changed by -1urad in pitch and +0.5urad in yaw, when measured from the start of the decrease in POP_A_LF.

To compare, TMSX alignment changed 0.02urad in pitch and 0.05urad in yaw.

I started by raising POP_A_LF  with TMSY yaw, and stepped the alignment slider by 0.05 at first and then increased that step size to 0.2, with a ramp time of 20 seconds, and made a step about every 4 minutes, which gave the ASC time to recover.

After some improvement in POP_A_LF, I switched to aligning TMSY pitch.

When I was done, POP_A_LF had increased from 14850 to 16100.

Plots attached:


Time history of this lock:

- Cheryl, JeffK, Kiwamu

Images attached to this report
Comments related to this report
cheryl.vorvick@LIGO.ORG - 23:34, Saturday 09 January 2016 (24822)

ASC during the drop and recovery of POP_A_LF

plot 1 - MICH P and Y and POP_A_LF - MICH noise and a glitch in POP_A_LF, just right of center in the plot,  starts the POP dive

plot 2 - PRC is unperterbed by all events

plot 3 - SRC moves away from zero as POP_A_LF drops

Images attached to this comment
cheryl.vorvick@LIGO.ORG - 23:36, Saturday 09 January 2016 (24823)

PRM, PR3, BS, ITMs, ETMs, and TMSs during the POP drop and recovery

Images attached to this comment