Displaying report 1-1 of 1.
Reports until 07:22, Tuesday 12 January 2016
H1 INJ (DetChar, INJ)
christopher.biwer@LIGO.ORG - posted 07:22, Tuesday 12 January 2016 (24888)
Summary of hardware injection tests on 1/11/16
Summary:

We scheduled 10 coherent CBC waveforms to be injected into H1 and L1 during observation mode (alog 24867). All 10 coherent waveforms were successfully performed once.

Waveforms:

The waveforms were generated by Salvo and John V.

The tagged version of the waveform generation tools was not used. The reason for not using the tagged version is that we wanted to inject precessing waveforms but we do not have a time-domain precessing approximant. Therefore Salvo, John had to make some edits to the waveform generation tools to use a frequency-domain approximant.

The waveforms were committed to the SVN.

The parameters files are in: https://daqsvn.ligo-la.caltech.edu/svn/injection/hwinj/Details/Inspiral/

The names of the parameter files are:
coherentbbh20_1135136337.xml
coherentbbh21_1135136336.xml
coherentbbh22_1135136336.xml
coherentbbh23_1135136337.xml
coherentbbh24_1135136337.xml
coherentbbh25_1135136337.xml
coherentbbh26_1135136336.xml
coherentbbh27_1135136336.xml
coherentbbh28_1135136335.xml
coherentbbh29_1135136336.xml

The waveform files are in: https://daqsvn.ligo-la.caltech.edu/svn/injection/hwinj/Details/Inspiral/H1/ and https://daqsvn.ligo-la.caltech.edu/svn/injection/hwinj/Details/Inspiral/L1/

The waveform file names are:
coherentbbh20_1135136337_H1.out
coherentbbh21_1135136336_H1.out
coherentbbh22_1135136336_H1.out
coherentbbh23_1135136337_H1.out
coherentbbh24_1135136337_H1.out
coherentbbh25_1135136337_H1.out
coherentbbh26_1135136336_H1.out
coherentbbh27_1135136336_H1.out
coherentbbh28_1135136335_H1.out
coherentbbh29_1135136336_H1.out
coherentbbh20_1135136337_L1.out
coherentbbh21_1135136336_L1.out
coherentbbh22_1135136336_L1.out
coherentbbh23_1135136337_L1.out
coherentbbh24_1135136337_L1.out
coherentbbh25_1135136337_L1.out
coherentbbh26_1135136336_L1.out
coherentbbh27_1135136336_L1.out
coherentbbh28_1135136335_L1.out
coherentbbh29_1135136336_L1.out

I'll request that Salvo, John include anything they used to generate the waveforms such that their waveforms are reproducible.

Schedule:

All ten injections were scheduled and successfully injected. The following was added to the schedule file:
1136584223 1 1.0 coherentbbh20_1135136337_

This injection was successful.

After this injection completed, we left observation mode briefly so that Jeff could turn off the PUM and UIM PCAL lines (alog 24872).

We then returned to observation mode and the following was added to the schedule:
1136586132 1 1.0 coherentbbh21_1135136336_
1136587232 1 1.0 coherentbbh22_1135136336_
1136588332 1 1.0 coherentbbh23_1135136337_
1136589432 1 1.0 coherentbbh24_1135136337_
1136590532 1 1.0 coherentbbh25_1135136337_
1136591632 1 1.0 coherentbbh26_1135136336_
1136592732 1 1.0 coherentbbh27_1135136336_
1136593832 1 1.0 coherentbbh28_1135136335_
1136594932 1 1.0 coherentbbh29_1135136336_

These injections were all successful.

GraceDB entries:

Therefore the following graceid, and end times of the injections is:
H215896 1136594946.67
H215895 1136593847.67
H215894 1136592746.63
H215893 1136591646.63
H215892 1136590545.64
H215891 1136589445.66
H215890 1136588345.67
H215889 1136587246.63
H215888 1136586146.67
H215880	1136584236.63

There were three erroenous gracedb entries, please ignore these:
H215887 3313.668306
H215886 2214.632416
H215885 1114.669055
Displaying report 1-1 of 1.