Summary: We scheduled 10 coherent CBC waveforms to be injected into H1 and L1 during observation mode (alog 24867). All 10 coherent waveforms were successfully performed once. Waveforms: The waveforms were generated by Salvo and John V. The tagged version of the waveform generation tools was not used. The reason for not using the tagged version is that we wanted to inject precessing waveforms but we do not have a time-domain precessing approximant. Therefore Salvo, John had to make some edits to the waveform generation tools to use a frequency-domain approximant. The waveforms were committed to the SVN. The parameters files are in: https://daqsvn.ligo-la.caltech.edu/svn/injection/hwinj/Details/Inspiral/ The names of the parameter files are: coherentbbh20_1135136337.xml coherentbbh21_1135136336.xml coherentbbh22_1135136336.xml coherentbbh23_1135136337.xml coherentbbh24_1135136337.xml coherentbbh25_1135136337.xml coherentbbh26_1135136336.xml coherentbbh27_1135136336.xml coherentbbh28_1135136335.xml coherentbbh29_1135136336.xml The waveform files are in: https://daqsvn.ligo-la.caltech.edu/svn/injection/hwinj/Details/Inspiral/H1/ and https://daqsvn.ligo-la.caltech.edu/svn/injection/hwinj/Details/Inspiral/L1/ The waveform file names are: coherentbbh20_1135136337_H1.out coherentbbh21_1135136336_H1.out coherentbbh22_1135136336_H1.out coherentbbh23_1135136337_H1.out coherentbbh24_1135136337_H1.out coherentbbh25_1135136337_H1.out coherentbbh26_1135136336_H1.out coherentbbh27_1135136336_H1.out coherentbbh28_1135136335_H1.out coherentbbh29_1135136336_H1.out coherentbbh20_1135136337_L1.out coherentbbh21_1135136336_L1.out coherentbbh22_1135136336_L1.out coherentbbh23_1135136337_L1.out coherentbbh24_1135136337_L1.out coherentbbh25_1135136337_L1.out coherentbbh26_1135136336_L1.out coherentbbh27_1135136336_L1.out coherentbbh28_1135136335_L1.out coherentbbh29_1135136336_L1.out I'll request that Salvo, John include anything they used to generate the waveforms such that their waveforms are reproducible. Schedule: All ten injections were scheduled and successfully injected. The following was added to the schedule file: 1136584223 1 1.0 coherentbbh20_1135136337_ This injection was successful. After this injection completed, we left observation mode briefly so that Jeff could turn off the PUM and UIM PCAL lines (alog 24872). We then returned to observation mode and the following was added to the schedule: 1136586132 1 1.0 coherentbbh21_1135136336_ 1136587232 1 1.0 coherentbbh22_1135136336_ 1136588332 1 1.0 coherentbbh23_1135136337_ 1136589432 1 1.0 coherentbbh24_1135136337_ 1136590532 1 1.0 coherentbbh25_1135136337_ 1136591632 1 1.0 coherentbbh26_1135136336_ 1136592732 1 1.0 coherentbbh27_1135136336_ 1136593832 1 1.0 coherentbbh28_1135136335_ 1136594932 1 1.0 coherentbbh29_1135136336_ These injections were all successful. GraceDB entries: Therefore the following graceid, and end times of the injections is: H215896 1136594946.67 H215895 1136593847.67 H215894 1136592746.63 H215893 1136591646.63 H215892 1136590545.64 H215891 1136589445.66 H215890 1136588345.67 H215889 1136587246.63 H215888 1136586146.67 H215880 1136584236.63 There were three erroenous gracedb entries, please ignore these: H215887 3313.668306 H215886 2214.632416 H215885 1114.669055