Displaying report 1-1 of 1.
Reports until 17:13, Tuesday 12 January 2016
X1 DTS
jonathan.hanks@LIGO.ORG - posted 17:13, Tuesday 12 January 2016 - last comment - 13:38, Friday 15 January 2016(24908)
Bad power supplies on x1seiex io chassis

While investigating an issue with x1seibsctim04 Jim Batch and I noticed that the power supply on the x1seiex IO chassis was dead.  We replaced the power supply with a spare unit from the self.  The new power supply appears to be getting 5v (some leds where lit), but it would not turn on (the fans would start to spin up and then stop).

Further investigation is needed.  For now x1seiex has been disconnected from the dolphin network and turned off.

Comments related to this report
jonathan.hanks@LIGO.ORG - 16:24, Wednesday 13 January 2016 (24931)

FRS 4218

https://services.ligo-la.caltech.edu/FRS/show_bug.cgi?id=4218

jonathan.hanks@LIGO.ORG - 13:38, Friday 15 January 2016 (24971)
From the FRS:

--- Comment #1 from richard.mccarthy@LIGO.ORG ---
Turns out the an ADC interface board had a short dragging the power supply
down.
Replaced the board and returned the unit to service.