Displaying report 1-1 of 1.
Reports until 22:26, Sunday 10 January 2016
H1 CAL (DetChar, INJ)
jeffrey.kissel@LIGO.ORG - posted 22:26, Sunday 10 January 2016 - last comment - 11:02, Wednesday 20 January 2016(24843)
H1 PCALX Line Injection Progress
J. Kissel, R. Savage, LHO Operators

Tallying up the progress so far on the schedule of PCALX excitations at high frequency (see plan in LHO aLOG 24802):
                                                        Achieved     Planned 
Frequency    Amplitude   Start Time      Stop Time      Duration     Duration    Success?
(Hz)         (ct)        (mm-dd UTC)     (mm-dd UTC)    (hh:mm)      (hh:mm)     (Yes / No, reason if no)
------------------------------------------------------------------------------------------------------------------------------
1001.3       35k         01-09 22:45     01-10 00:05    01:20         01:00      Yes

1501.3       35k         01-09 21:12     01-09 22:42    01:30         01:00      Yes

2001.3       35k         01-09 18:38     01-09 21:03    02:25         02:00      Yes

2501.3       40k         01-09 12:13     01-09 18:31    06:18         02:00      Yes
 
3001.3       35k         01-10 00:09     01-10 04:38    04:29         04:00      Yes    

3501.3       35k         01-10 04:41     01-10 12:07    05:26         06:00      Good Enough!

4001.3       40k         01-09 04:11     01-09 12:04    07:55         08:00      Good Enough!

4501.3       40k         01-10 17:38     01-11 06:02    12:24         12:00      Yes

5001.3       40k         01-11 06:18     on-going          (as long as we can get)


Thanks to all of the operators who have been dilligently caring for these lines while we sleep!

For the record, while these PCALX calibration lines are on, the majority (if not all) of the range is consumed, so we cannot perform PCALX hardware injections.
Comments related to this report
sudarshan.karki@LIGO.ORG - 23:22, Sunday 17 January 2016 (25003)

I used the high frequency calibration lines injected above to estimate the sensing function at those frequencies. For this analysis, SLM Tool was used to obtain the line amplitude and phase of these calibration lines at different relevant channels.

Sensing Function = DARM_ERR[ct] / PCAL_TXPD[m]

The DARM_ERR signal is dewhitened and the PCAL_TXPD is corrected to get metres using the scheme described in G1501518. 

Furthermore, ratio of GDS/Pcal is calculated and is included in the attached plot.

Non-image files attached to this comment
laura.nuttall@LIGO.ORG - 11:02, Wednesday 20 January 2016 (25045)

A data quality flag has been created to capture times when these extra PCAL lines were in the data. It is H1:DCH-EXTRA_PCAL_LINES:1 and a description of this flag can be found on the detchar wiki.