Mid-SHIFT SUMMARY:
IFO Locked at NLN 78Mpc 02:57UTC
Commissioners working 54Mpc
SDF is LIT up Red. Sheila mentioned that it probably hasn’t been cleared since the power outage?
µSei Z-axis is riding above the 90%ile. EQ bands are ≈.08µm/s. Winds are ≤15mph
I started a cleanup of SDF by doing some reverts on TRAMP values (some of which I changed in SUS trying to re-align yesterday). The changes effected were on: HAMs 2,4,5,6 ISI; and SUS-BS,IM, PR2, SR2, and SR3. Also, the Gain/State_Good on the BS ISI was reverted. If 'your' sub-system(s) are showing changes in SDF due to power outage recovery or just trying to make things mo' betta, please have a look and accept or revert.
ALL LHO SEI Platform SDFs were green'd Wednesday morning. Any SDF reds Thursday evening were not related to the power outage.
These changes relate to Jim & me making some guardian changes; we should have more quickly updated the SDFs.