Reports until 16:31, Saturday 23 January 2016
H1 ISC (DetChar, ISC)
gabriele.vajente@LIGO.ORG - posted 16:31, Saturday 23 January 2016 - last comment - 12:21, Monday 25 January 2016(25123)
Band stop in PRCL

We noticed a small bump in DARM at about 360 Hz, coherent with PRCL. We added a 270-430 Hz elliptic band-stop. DARM improved and the coherence is almost gone. We are losing 9 degrees of phase at 50 Hz (PRCL UGF).

The filter is implemented in the SUS filter bank.

Images attached to this report
Comments related to this report
gabriele.vajente@LIGO.ORG - 12:21, Monday 25 January 2016 (25143)

The bandstop filter is now engaged by the guardian in the NOISE_TUNING step.