I ran BruCo on one hour of data from last night. The report is available here:
https://ldas-jobs.ligo.caltech.edu/~gabriele.vajente/bruco_1137640217/
At low frequency, SRCL and DHARD_P are the largest contributions. SRCL is still a factor of few below the measured noise, while DHARD is very close around 14 Hz.
There is coherence with magnetometers (still far from the measured noise)
No significant broadband coherence in the mistery noise region.