Displaying report 1-1 of 1.
Reports until 18:18, Tuesday 26 January 2016
H1 CDS (CDS)
jenne.driggers@LIGO.ORG - posted 18:18, Tuesday 26 January 2016 - last comment - 10:25, Wednesday 27 January 2016(25188)
DTT only gets one channel at a time

[JimW, Jenne, EvanH, Kiwamu, Sheila, Gabriele]

The new version of DTT seems only capable of getting a single channel of data at a time. 

We have tried several different kinds of channels, and DTT will only give you the first channel in the list.  No good.

Comments related to this report
james.batch@LIGO.ORG - 19:16, Tuesday 26 January 2016 (25189)

Attached is a plot showing multiple channels of data captured with DTT.

If you want to use the old version, in a terminal enter the command

source /ligo/apps/linux-x86_64/gds-2.17.1.1/etc/gds-user-env.sh

Then start diaggui in the same terminal.

 

Images attached to this comment
keita.kawabe@LIGO.ORG - 08:50, Wednesday 27 January 2016 (25195)

I did some quick test.

The problem I found is that the channel data is fetched only when YOU SELECT THE CHANNELS FROM THE DROP-DOWN TREE SELECT BOX.

When you type the channel name into an empty channel, or copy & paste, that channel is ignored.  This was not the case with older versions.

Once you select the channel name from the drop-down select box for a particular channel number, you can manually modify or delete and copy and paste an entirely new name for that channel number, and it works as expected.

Reported the problem to Jim.

corey.gray@LIGO.ORG - 10:25, Wednesday 27 January 2016 (25197)

Was going to submit an FRS for this, but see Jenne already did this (#4296).

Displaying report 1-1 of 1.