Displaying report 1-1 of 1.
Reports until 11:43, Wednesday 27 January 2016
H1 ISC (ISC, TCS)
aidan.brooks@LIGO.ORG - posted 11:43, Wednesday 27 January 2016 (25200)
Added fast polarization photodetectors to the HWS table

We added and aligned the fast photodetectors (PDA50B) to the HWS table, per T1500579. The outputs from these photodetectors go into a whitening board (D1500430). The input channels in the ADC are adc0_22 and adc0_23 in the TCS CO2 model.

Alignment:

We used an IR card with mounted in a C-Ring and the Green Beam from the ALS to align to the center of the aperture on the photodiodes. See the before and after alignment photos:

 

 

 

Also attached is a photo of the whitening board.

Calibration:

The input channels in the real-time code are: H1:TCS-IFO_POLZ_S_HWS and H1:TCS-IFO_POLZ_P_HWS.

The filter banks in these channels:

  1. Undo the whitening board (2x poles at 0.5Hz and 2x zeros at 10.9Hz)
  2. Convert from counts to volts
  3. Convert from volts to amps (+50dB transimpedance setting of PDA50B)
  4. Convert from amps to Watts (divides by response = 0.56 A/W at 1064nm)

Also, the following DC offsets are added at the input based on measurements of the background value when the photodiodes were not illuminated:

From here, the outputs go into a 2x4 matrix for combination to produce S and P estimates for the power incident on the BS_AR surface. A rough estimate for these values are as follows:

Based on the complex reflectivites of the BS for S and P, the ratio of S to P at the AS PORT increases by a factor of 39 from the BS_AR surface. We use the following parameters to calculate the polarization angle (in radians) at the AS PORT. 