Displaying report 1-1 of 1.
Reports until 14:39, Tuesday 02 February 2016
H1 TCS (TCS)
aidan.brooks@LIGO.ORG - posted 14:39, Tuesday 02 February 2016 (25315)
HWS SLED TECs now working correctly

I finally managed to get the HWS TECs working on the superluminescent diodes. The problem was that the trimpots on the LDTC0520 drivers were not set correctly. Per page 11 of the manual, for a SLED with a thermistor and a TEC, we use trimpot LIM_A to set the cooling current limit and LIM_B to set the heating current limit.

The actual temperature on the SLED now goes to the set point temperature.

Displaying report 1-1 of 1.