jeffrey.bartlett@LIGO.ORG - posted 16:04, Friday 05 February 2016 (25421)
Ops Day Shift Summary
Activity Log: All Times in UTC (PT)

15:15 (07:15) Chris – Beam tube sealing ~ 100 to 150 yards from End-X
17:06 (09:06) Reset H1SUSETMY Timing error
17:24 (09:24) Alastair & Nutsinee – Going to IO table near HAM4.
17:26 (09:26) Hugh – Doing Guardian restarts WP #5723
18:06 (10:06) Kyle – Going to Y-Arm compressor room
19:08 (11:08) Alastair & Nutsinee – Out of the LVEA
19:43 (11:43) Ken (K&S Electrical) – Going to Y-Arm compressor room
20:15 (12:15) Kyle – Back from Y-Arm
20:20 (12:20) Ken – Back from Y-Arm
20:41 (12:41) Nutsinee – Going to check HWS in the LVEA
21:12 (13:12) Jim & Carlos – Going to check HWS computer at End-Y 
21:28 (13:29) Kyle – Going out to Y-Arm compressor room
21:40 (13:40) Jim & Carlos – Back from End-Y
22:29 (14:29) Carlos – Going to End-Y to swap hard drive on HWS computer
23:47 (15:47) Kyle – Back from End-Y
23:57 (15:57) Locked at NOMINAL_LOW_NOISE	
00:00 (16:00) Turn over to Travis



End of Shift Summary:

Title:  02/05/2015, Day Shift 16:00 – 00:00 (08:00 – 16:00) All times in UTC (PT)

Support: Kiwamu, Jim, Masayunki, Jenne, Jim W.              
 
Incoming Operator: Travis

Shift Detail Summary:  After an initial alignment, spent most of the morning trying to relock. Still losing lock at DRMI_LOCKED. Kiwamu looking into the problem, found the SR3 Cage Servo was noisy, which may be causing the lock loss problems. About this time, there was a mag6.4 earthquake in Taiwan, with an R-Wave velocity of 5.3um/s. The seismic signal rang up to ~ 3.0um/s. Put the IFO into down until things settle down.

After seismic rang down from EQ tried relocking. Had to tune MITCH_DARK. All other alignments were OK. Relocked at NOMINAL_LOW_NOISE. Turnover to Travis and the commissioners. 	 