AS_Air camera moved

Elli, Cao

I have moved the AS_Air camera 30cm along the beampath, to optimise this camera location for an SRC gouy phase measurement.  See attached photo.  The camera is now 20cm in front of the beam waist, instead of 10cm behind it.  We now measure 10.4cm between the beamsplitter (to CAM_17) and AS_Air.
  I have left some clamps in place to mark the original position of this camera, so we can move it back quickly if necessary.

OPERATORS NOTE:  The spot position on the AS_Air Camera will now be somewhat different.  Take note during during the intitial alignment stage.  When aligning the BS, the beam now looks brighter on the AS_Air camera.