Displaying report 1-1 of 1.
Reports until 15:39, Wednesday 10 February 2016
H1 CAL (CAL)
craig.cahillane@LIGO.ORG - posted 15:39, Wednesday 10 February 2016 (25496)
Response Function Comparisons with Individual Frequency Dependence Systematic Errors Removed
C. Cahillane

There was some concerned voiced by Alan and Peter about the LLO uncertainty budget combined with the systematic error corrections at around 100 Hz at gpstime = 1126259461.
This post is merely to mirror the study I did at LLO with a similar one at LHO explaining why we do not see the LLO 'hump' at LHO.  See LLO aLOG 24796
I have included the LHO C01 vs C03 response functions systematic error and statistical uncertainty plot. (See PDF 1) 

I began with the "perfect" C03 version of calibration response which includes all systematic corrections.  Then, one by one I removed each systematic correction and compared it to the original C03 response: (See PDF 2)
Sensing:    C_r (Plot 1)
Actuation:  A_tst, A_pum, and A_uim (Plot 2, 3, and 4)
Kappas:     kappa_tst, kappa_pu, kappa_C, and f_c (cavity pole) (Plot 5, 6, 7, and 8)

So you don't have to go through and view every plot yourself, I have compiled all of the systematic error values at 100 Hz for each of the parameters:
C_r = 0.98932
A_{tst} = 1.0018
A_{pum} = 0.99381
A_{uim} = 1
kappa_{tst} = 1.0251
kappa_{pu} = 0.99465
kappa_C = 1.002
f_C = 1

Total Syst Error = +0.0068

So the total systematic error at 100 Hz is < 1% because it is countered by the C_r, A_pum, and kappa_pu systematic errors.