Reports until 11:43, Sunday 14 February 2016
H1 SUS (CDS, SUS)
sheila.dwyer@LIGO.ORG - posted 11:43, Sunday 14 February 2016 - last comment - 11:34, Tuesday 16 February 2016(25539)
somethig wrong with TMSX osems, strange results from DTT

In the first attachment you can see that something happened to the TMS osems on Jan 21st that makes the peak to peak noise increse by more than a factor of 10. This is still the case. 

I then took a look at the osem spectra, (the fast channels which are not DQ) and saw a 16 Hz comb in RT and SD (second screenshot).  Without saving I re ran the measurement including TMSY channels for comparison, and then saw that the comb appeared to have gone away.  Spectra of the 256 Hz DQ channels from the time when I originally saw the 16Hz comb are in the third attachment, there is no comb here. 

The last attached screenshot shows the osem spectra for both TMSs that I am measureing now, there is some oscillation around 1800 Hz.  This is very similar to the behavoir reported in 25062  and 20078

Images attached to this report
Non-image files attached to this report
Comments related to this report
keita.kawabe@LIGO.ORG - 11:34, Tuesday 16 February 2016 (25563)

Seems like everything in ETMX chamber is polluted by TMSX OSEM oscillation.

This is an annoyance, some time this week Richard will do the same modification as SR3 mentioned in alog 25516.

Images attached to this comment