Displaying report 1-1 of 1.
Reports until 17:41, Saturday 13 February 2016
H1 ISC
kiwamu.izumi@LIGO.ORG - posted 17:41, Saturday 13 February 2016 - last comment - 20:27, Sunday 14 February 2016(25535)
20 dB gains are back in soft loops

[Evan; Rana; Kiwamu];

We restored the 20 dB gains (that have been commented out for long time) in all the soft loos. We still have some suspicision that the ISS may be doing something bad causing locklosses. In order to separate the issues, we decided to gain them up. If one wants to get rid of them, just comment out lines 1990-1993 in the ISC_LOCK guardian.

Comments related to this report
sheila.dwyer@LIGO.ORG - 20:27, Sunday 14 February 2016 (25542)

The ASC loops had a slow oscillation with these 20 dB gains today, so we commented them out again. 

Displaying report 1-1 of 1.