Displaying report 1-1 of 1.
Reports until 13:09, Tuesday 16 February 2016
H1 CDS
david.barker@LIGO.ORG - posted 13:09, Tuesday 16 February 2016 (25567)
front end models use of channel access

Aidan is making changes to h1tcscs which requires reading EPICS channels from the Beckhoff system. Here is the current number of H1 models which use CA to read/write data to external systems.

model with ez_ca_read parts number of channels read
h1ioppemmx* 1
h1ioppemmy* 1
h1odcmaster 5
h1pslpmc 1
h1sushtts 1
h1tcscs 14

 

model with ez_ca_write parts number of channels written
h1psliss 16
h1pslpmc 1

* The mid station IOP models lack a full timing system (no IRIGB signal) and instead get their GPS time from the DAQ via Channel Access.

The list of EZ_CA_[READ/WRITE] channels was obtained by:

cd /opt/rtcds/lho/h1/release/src/epics/fmseq

ls|grep -v "_daq"|xargs grep "EZ_CA_READ"

ls|grep -v "_daq"|xargs grep "EZ_CA_WRITE"