Reports until 16:35, Tuesday 16 February 2016
H1 TCS (TCS)
aidan.brooks@LIGO.ORG - posted 16:35, Tuesday 16 February 2016 (25573)
Estimated thermal lenses in TCS model

I've added a block to the TCS model to estimate the real-time thermal lenses in each of the test masses and the surface curvature of each of the test masses.

OPTIC_LENS.mdl

The main new library block, shown in the attached figure, is OPTIC_LENS which takes as inputs:

Each of these inputs goes into a filter that contains (or will contain) the transfer function for power to diopters for that specific actuation. These are:

which are summed together to yield. These are outputs for the model:

h1tcscs.mdl

There are four of these blocks in the main TCS model h1tcscs.mdl - one for each test mass. Although the ETMs contain inputs for CO2 lasers, these are grounded. See the attached figure.

The outputs from the four blocks are currently terminated. I plan on updating the model to create channels for COMMON and DIFFERENTIAL MICHELSON and ARM lenses and others, as required. This will be after I've verified that the model and filters are all working correctly.