CDS maintenance summary, Tuesday 16th February

TCS model change. WP5732

Dave, Aidan:

Aidan made model changes to h1tcscs.mdl 

Buried EY Seismometer added to h1isietmy model. WP5733

Jeff, Robert, Dave:

h1isietmy was modifed to read the external seismometer, these channels were added to the science frame.

Adding all Vacuum Controls channels to the DAQ. WP5731

Dave:

All the vacuum controls channels were added to the DAQ. Increased the number of channels from 280 to 1777

DAQ restart

Jim, Dave:

DAQ was restarted to support all the above changes. After several hours h1fw1 became unsynchronized to h1fw0 (we had not seen this before). Restarting h1fw1 fixed this.

GLIBC patching

Dave: