Reports until 09:51, Friday 19 February 2016
H1 ISC
keita.kawabe@LIGO.ORG - posted 09:51, Friday 19 February 2016 - last comment - 14:50, Friday 19 February 2016(25634)
RF90 whitening/awhitening mismatch.Who's doing what?

RF90 phase for ASC-AS_A was totally off this morning but AS_B was good, it turns out that somehow the whitening and awhitening  didn't match for AS_A (first attachment).

In the attached 2-days trend of analog whitener (ch1) and digital anti-whitener (ch2) (second attachment),  the second stage whitener/awhitener was turned off by me yesterday morning and it was good, was turned back on by me later and it was good for a while, but something turned off the digital quietly after that.

I wanted to see the guardian log but it's already in the maze of cryptic file names and it's a royal pain.

Images attached to this report
Comments related to this report
keita.kawabe@LIGO.ORG - 14:50, Friday 19 February 2016 (25641)

Turns out that when all WFS settings were reverted back yesterday evening (so that Den/Kiwamu/Evan can continue with full lock), 90MHz settings were also reverted back, including the whitening setting.