Displaying report 1-1 of 1.
Reports until 09:41, Friday 19 February 2016
H1 SEI
jim.warner@LIGO.ORG - posted 09:41, Friday 19 February 2016 - last comment - 11:04, Tuesday 23 February 2016(25636)
Corner station ISIs should use

Yesterday, I switch the HAM3 ISI to use the "HAM5" STS (now, actually in the biergarten), did an initial measurement to make sure the ISI was performing okay, then left it overnight. This morning I compared it's performance to HAM2, and I think we should switch all of the ISIs to used this seismometer. Attached 3 spectra show the GS13 spectra for X,Y and Z over a ~1 hour period overnight. In all DOF's over most frequencies, HAM3 does better than HAM2 now, where previously they had performed similarly (excepting HAM3's transient .6hz mystery line). Most important, HAM3 does much better where sensor correction gets us most of our isolation (~.1-1hz). This is an easy change, and should be totally transparent.

Images attached to this report
Comments related to this report
jeffrey.kissel@LIGO.ORG - 10:23, Friday 19 February 2016 (25639)
I can't do more than just speculate at the moment, but I wonder if HAM3's better performance of the sensor correction than HAM2 isn't because the sensor is better but because HAM3 is ~15 [m] closer than HAM2. Is HAM2 using the "HAM2" STS-A, and is it still right under HAM2? I've lost track of Hugh's STS juggling...
hugh.radkins@LIGO.ORG - 11:04, Tuesday 23 February 2016 (25680)

All corner station platforms were using the ITMY (STS2-B) sensor, but Jim has been switching the platforms over to the HAM5 (STS2-C) sensor which has been moved to the BierGarten near STS2-B.