Partial recovery of sensitivity

Den, Kiwamu, Evan

Tonight we again made it to low noise, although the locking procedure is still not robust enough. In the end, it seems that the sensitivity degredation is not due to a new mystery noise, but rather is a consequence of a shift in the interferometer alignment and some left-over temporary equipment.

List of changes/observations for locking is as follows:

Once we reached the low-noise state, we again saw the excess noise that has been bothering us for the past few days. We were able to partially mitigate this as follows:

The sensitivity is now 70–76 Mpc.

Finally, we looked for high-frequency frequency noise downconverting into DARM. We didn't see anything, but here is what we did:

Comments related to this report
evan.hall@LIGO.ORG - 18:14, Saturday 20 February 2016 (25651)

We also made some tweaks to the ALS locking:

  • The resonant gain in the EX UIM drive for the microseism seemed a bit too narrow (0.2 Hz, Q of 3, 10 dB peak), so it is now slightly broader, giving at least a few dB of suppression from 0.1 to 0.2 Hz.
  • Previously, offloading of the IMC VCO to EX UIM was engaged only after ALS DIFF had finished locking. Offloading is now engaged immediately after the handoff of the IMC to ALS COMM (i.e., immediately before the DIFF locking starts). We did this because we were seeing about half of the ALS DIFF lock acquisitions failing because of IMC-F saturations.
  • We tweaked the timing for engaging the EX UIM boost and resonant gain. When locking ALS DIFF, we spend 10 seconds ramping on the DARM gain from 0 % to 10 % of its final value, and then another 10 seconds ramping the DARM gain from 10 % to 100 % of its final value. Previously, we only engaged the extra EX UIM filters after the gain had reached 100 %, but this means the EX ESD can more easily saturate from seismic fluctuations. So we now engage the extra EX UIM filters as the DARM gain is ramping to 100 %.
evan.hall@LIGO.ORG - 03:38, Sunday 21 February 2016 (25653)

Attached are transfer functions of IMC jitter (sensed by the IMC WFS) into DARM, compared against the previous TFs measured in September. One can see that the pitch coupling is higher by more than a factor of 3.