Displaying report 1-1 of 1.
Reports until 14:18, Monday 22 February 2016
H1 ISC
daniel.sigg@LIGO.ORG - posted 14:18, Monday 22 February 2016 (25662)
RF Amplitude Stabillization for 9MHz

(Keita Daniel)

We mounted the 9 MHz RF AM Stabilization chassis in the CER in preparation of tomorrows installation in the PSL enclosure. The remote control is working fine.

Comment 1: The little back panel PCB became loose during shipping and needed to be reseated. It is important to make sure it is correctly centered, since the connectors are not keyed (the power supply will blow, if it is shifted by one).

Comment 2: In a Frankenstein experiment someone disassembled the high power sensor for the RF power meter and then equipped it with a different sensor head. Please don't. The sensor head and power attenuator constitutes a single sensor and should never be taken apart.

Displaying report 1-1 of 1.