RF Amplitude Stabillization for 9MHz

(Keita Daniel)

We mounted the 9 MHz RF AM Stabilization chassis in the CER in preparation of tomorrows installation in the PSL enclosure. The remote control is working fine.

Comment 1: The little back panel PCB became loose during shipping and needed to be reseated. It is important to make sure it is correctly centered, since the connectors are not keyed (the power supply will blow, if it is shifted by one).