Attached are 7 day pitch, yaw, and sum trends for all active H1 optical levers. Closing FAMIS #4393.
Notes:
Everything here looks good. We need to keep an eye on the HAM2 oplev (assuming anyone is actually using it), it is getting close to the edge of its linear operating range (~±30 µrad).
We'll keep an eye on ETMy yaw as well. Its linear operating range is large (on the order of ±50 µrad) so a re-zeroing is strictly necessary, but it is used for weekly SUS charge measurements so a tighter operating range might be desirable.