Alignment shifts of IO IMs (IM1-3) in H1 also occurring in L1:

My investigation into the alignment shifts of the H1 IMs (IM1, IM2, IM3) led me to investigate the IMs at LLO in L1.

I have identified three events where the L1 IMs changed alignment for the same alignment drive.

Chart-1 shows L1 IO IM1-3 optics on Sept. 13th, Nov. 14th, and Nov. 25th, when earthquakes tripped the L1 HAM2 ISI.

The chart also shows the amount of shaking of the L1 IM optics and the L1 HAM2 ISI.

This data shows that the alignment of the IMs in L1 are vulnerable to alignment shifts after a HAM2 ISI trip. 

Corresponding alogs regarding LHO H1 IO IM1-3 alignment shifts are H1alog22913, H1alog22956, H1alog23415, and H1algo25075.