Reports until 16:19, Thursday 25 February 2016
LHO VE
kyle.ryan@LIGO.ORG - posted 16:19, Thursday 25 February 2016 (25730)
Cut out shorted section of X2-8 beam tube ion pump HV cable
Kyle, Joe D. 

The plan now is to splice-in the longest piece of the excess good cable left over from the initial install.  The resulting o.a.l of this repaired cable will be very close to what is needed but may require routing through a, yet-to-be-created, wall penetration into the adjacent room where the pump controller resides - or not.