evan.hall@LIGO.ORG - posted 18:31, Friday 26 February 2016 (25733)
Ringdowns of violin-mode first harmonics

During O1 we had several long lock stretches with all test mass violin mode damping turned off (for all harmonics). The longest stretch that I know of is 35 hours, from 2015–12–19 07:00:00 Z to 2015–12–20 18:00:00 Z.

Here I give the quality factors of the violin mode first harmonics. The test mass identifications are taken from the mode table on the wiki. Of the 32 first harmonics, one was not seen in the data, and a further six do not have clear ringdowns in their envelopes. We had some other locks with no damping, so we should look at these to see if the behavior of these seven modes makes more sense.

The lowest Q observed was 0.2×109.

Freq. [Hz] TM Q (×109) Notes
500.054 IX 2.0  
500.212 IX 1.7  
501.092 IX 1.8  
501.208 IX 1.1  
501.256 IX Did not ring down
501.452 IX 1.3  
502.621 IX 1.8  
502.744 IX Did not ring down
501.608 IY 1.7  
501.682 IY
Did not ring down
Did not ring down
Did not ring down
501.749 IY 1.1  
501.811 IY 1.6  
503.007 IY 1.9  
503.119 IY 1.9  
504.805 IY 1.7  
504.872 IY 2  
505.587 EX 0.7 Middling quality data
505.707 EX Not seen
505.710 EX Did not ring down
505.805 EX 1.6  
506.922 EX 1.1  
507.159 EX 1.2  
507.194 EX 1.7  
507.391 EX 1.3  
507.992 EY 1.6  
508.010 EY Did not ring down
508.146 EY 0.3 Middling quality data
508.206 EY 0.2 Middling quality data
508.220 EY 1.9  
508.289 EY 1.3  
508.585 EY 0.7  
508.661 EY Did not ring down