Reports until 11:18, Monday 29 February 2016
H1 IOO (IOO)
cheryl.vorvick@LIGO.ORG - posted 11:18, Monday 29 February 2016 - last comment - 08:31, Wednesday 02 March 2016(25781)
IM2 (PMMT1) oscillating after Satellite module fix

IM2 position is now oscillating by 5urad in pitch and yaw after satellite module fix on Feb. 23.

Three plots attached:

Images attached to this report
Comments related to this report
edmond.merilh@LIGO.ORG - 11:33, Monday 29 February 2016 (25784)

That Sat amp doesn't qualify as fixed at this point. The modification is not currently installed. See Richard McCarthy for details.

edmond.merilh@LIGO.ORG - 08:31, Wednesday 02 March 2016 (25832)

3/1/2016 The modification has been added.