Displaying report 1-1 of 1.
Reports until 14:42, Monday 29 February 2016
H1 GRD
thomas.shaffer@LIGO.ORG - posted 14:42, Monday 29 February 2016 (25787)
New test in DIAG_MAIN

Test for the ISC whitening and anit-whitening filters to be set equivalently. Daniel and Keita asked me to do this last week and I finally got around to it today.

It has to check 156 pairs of channels, so with that many channel acces calls it slows down the exc time a bit. When I get time again I will try to make it faster.

 

Code sample:



    omc_tups = [('OMC-DCPD_A_WHITEN_SET_{}'.format(i),'OMC-DCPD_B_WHITEN_SET_{}'.format(i)) for i in range(1,4)]
    all_dem_tups = [('{}_WHITEN_FILTER_{}'.format(pre,i), '{}_AWHITEN_SET{}'.format(pre,i)) for pre in prefix for i in range(1,4)] + omc_tups

    for x in all_dem_tups:
        if ezca[x[0]] != ezca[x[1]]:
            yield '{} and Anti-whiten not equal'.format(x[0])

Where prefix is a list of all the filter banks that share common whiten/Awhitening, but the OMC is special, apparently.