Suspension Sat Amp Mods
Finished adding Caps to the Negative regulator per latest dwg. Today we completed the ITMx,ITMy,BS, and all of Ham5 and Ham6 Suspensions.  Also verified and corrected were needed Ham2 optics.
This should stem any oscillations caused by the long cables from the SAT amp side.
Comments related to this report
jeffrey.kissel@LIGO.ORG - 09:34, Wednesday 02 March 2016 (25834)DetChar
I've verified with Richard that this concludes the H1 SatAmp upgrade as per Integration Issue 1129, DCN E1100767, and G1100856. 

Nice work gents!

Stay tuned for a systematic check of how-and-if it has improved the high frequency oscillations this upgrade was intended to fix.