IM2 (PMMT1) oscillating after Satellite module fix

IM2 position is now oscillating by 5urad in pitch and yaw after satellite module fix on Feb. 23.

Three plots attached:

Images attached to this report
Comments related to this report
edmond.merilh@LIGO.ORG - 11:33, Monday 29 February 2016 (25784)

That Sat amp doesn't qualify as fixed at this point. The modification is not currently installed. See Richard McCarthy for details.

edmond.merilh@LIGO.ORG - 08:31, Wednesday 02 March 2016 (25832)

3/1/2016 The modification has been added.