Since the ISI will trip its watchdog when the suspension it carries trips, a path to the particular tripped suspension seems convenient. This already existed for the HAMs and I've now added it to the BSC ISIs.
On the ISI OVERVIEW medm, there is a Payload button in the middle left. This will be ringed in red if the suspension is either tripped or its model stopped. The PAYLOAD medm has a link to the suspension(s) (very convenient for the likes of HAM2,) and an override button. If the SUS model is not running, the operator can hit the override button and untrip the ISI watchdog. The override does not work for a running suspension. The attached shows the medms.
Had to add sus variables to get the correct SUS medms to the ISI overview_macro files:
hugh.radkins@opsws10:bscisi 0$ pwd
/opt/rtcds/userapps/release/isi/h1/medm/bscisi
hugh.radkins@opsws10:bscisi 0$ svn commit -m "Added sus medm style for payload display"
Sending bscisi/H1_isibs_overview_macro.txt
Sending bscisi/H1_isietmx_overview_macro.txt
Adding bscisi/H1_isietmy_overview_macro.txt
Sending bscisi/H1_isiitmx_overview_macro.txt
Sending bscisi/H1_isiitmy_overview_macro.txt
Transmitting file data .....
Committed revision 12788.
hugh.radkins@opsws10:bscisi 0$
And, edited two ISI medms:
hugh.radkins@opsws10:bscisi 0$ pwd
/opt/rtcds/userapps/release/isi/common/medm/bscisi
hugh.radkins@opsws10:bscisi 0$ svn commit -m "Completing links to SUS medm via PAYLOAD"
Sending bscisi/ISI_CUST_CHAMBER_OVERVIEW.adl
Sending bscisi/ISI_CUST_CHAMBER_PAYLOADMON.adl
Transmitting file data ..
Committed revision 12789.
hugh.radkins@opsws10:bscisi 0$