Tried the following:
Also applies to a range of other ASC channels, like CHARD_Y_EXC, INP2_P_EXC, CHARD_P_A_EXC, etc.
I tried an excitation in LSC-XARM_EXC and it worked fine.
I tried awg clear 19 * in the diag terminal; no change.
Am I missing something here?
the awgtpman process on h1asc was reporting the incorrect channel number for this channel (H1:ASC-CHARD_P_EXC is chnnum 20298 but the awgtpman was reporting it as 20304). Interestingly diaggui was able to excite CHARD_P_EXC despite the error but awggui was not. I also saw an error along the lines of "awgtpman cannot start as it is already running" and suspect the issue was from the bad restart of h1asc yesterday when there was a collision of DAC channels between h1asc and h1ascimc.
I killed to running awgtpman_h1asc and restarted it, all looks good now.