Displaying report 1-1 of 1.
Reports until 21:30, Friday 04 March 2016
H1 AOS
evan.hall@LIGO.ORG - posted 21:30, Friday 04 March 2016 - last comment - 01:59, Saturday 05 March 2016(25885)
X arm common offloading rails during ALS/IR search

It is happening pretty consistently during each lock acquision.

It looks like it started around noon today.

Images attached to this report
Comments related to this report
evan.hall@LIGO.ORG - 23:50, Friday 04 March 2016 (25886)

Shuttering ALS now causes violent fluctuations at the AS port, and causes the test masses to saturate.

evan.hall@LIGO.ORG - 01:59, Saturday 05 March 2016 (25888)

This is apparently because of a rewrite of the LOCKING_ALS state in ISC_LOCK which was not tested.

Both X and Y tidal are requested to go to "transition" (i.e., IMC-F offloading enabled), but Y does not do so. This causes X to offload IMC-F by itself (unsuccessfully).

Sleeps must be added to the guardian code in order to make both X and Y actually go to the "transition" state.

I have also removed some logging commands in the run method (as these continually output garbage to the logfile while the guardian loops over that method).

Displaying report 1-1 of 1.