sheila.dwyer@LIGO.ORG - posted 20:33, Monday 29 February 2016 - last comment - 16:16, Saturday 05 March 2016(25788)
change to whitening filters for DELTAL_EXTERNAL

We have changed the whitening filters in CAL_DELTAL_EXTERNAL_DQ, to the filter described in

25785

We are now using 6 zeros at 0.3 Hz and 6 poles at 30 Hz.  Hopefully this will take care of the aliasing problem with DTT, and we can use the calibrated channel when making comparisons with seismic/ sus or PEM channels.  