Displaying report 1-1 of 1.
Reports until 09:33, Tuesday 08 March 2016
H1 SEI
thomas.shaffer@LIGO.ORG - posted 09:33, Tuesday 08 March 2016 (25931)
T240 Centering FAMIS #4366 and Bonus STS

All T240s prrof masses that within healthy range (< 0.3 [V]). Great!


Here's a list of how they're doing just in case you care:
ETMX T240 1 DOF X/U = 0.077 [V]
ETMX T240 1 DOF Y/V = 0.094 [V]
ETMX T240 1 DOF Z/W = 0.119 [V]
ETMX T240 2 DOF X/U = -0.199 [V]
ETMX T240 2 DOF Y/V = -0.246 [V]
ETMX T240 2 DOF Z/W = -0.094 [V]
ETMX T240 3 DOF X/U = 0.093 [V]
ETMX T240 3 DOF Y/V = -0.087 [V]
ETMX T240 3 DOF Z/W = 0.06 [V]
ETMY T240 1 DOF X/U = 0.03 [V]
ETMY T240 1 DOF Y/V = -0.042 [V]
ETMY T240 1 DOF Z/W = 0.005 [V]
ETMY T240 2 DOF X/U = -0.168 [V]
ETMY T240 2 DOF Y/V = 0.029 [V]
ETMY T240 2 DOF Z/W = 0.132 [V]
ETMY T240 3 DOF X/U = -0.001 [V]
ETMY T240 3 DOF Y/V = -0.003 [V]
ETMY T240 3 DOF Z/W = 0.1 [V]
ITMX T240 1 DOF X/U = -0.023 [V]
ITMX T240 1 DOF Y/V = 0.275 [V]
ITMX T240 1 DOF Z/W = 0.202 [V]
ITMX T240 2 DOF X/U = 0.24 [V]
ITMX T240 2 DOF Y/V = 0.262 [V]
ITMX T240 2 DOF Z/W = 0.296 [V]
ITMX T240 3 DOF X/U = 0.064 [V]
ITMX T240 3 DOF Y/V = 0.247 [V]
ITMX T240 3 DOF Z/W = 0.239 [V]
ITMY T240 1 DOF X/U = 0.192 [V]
ITMY T240 1 DOF Y/V = 0.068 [V]
ITMY T240 1 DOF Z/W = 0.116 [V]
ITMY T240 2 DOF X/U = 0.196 [V]
ITMY T240 2 DOF Y/V = 0.266 [V]
ITMY T240 2 DOF Z/W = 0.214 [V]
ITMY T240 3 DOF X/U = 0.121 [V]
ITMY T240 3 DOF Y/V = 0.214 [V]
ITMY T240 3 DOF Z/W = -0.149 [V]
BS T240 1 DOF X/U = 0.054 [V]
BS T240 1 DOF Y/V = 0.091 [V]
BS T240 1 DOF Z/W = 0.22 [V]
BS T240 2 DOF X/U = 0.162 [V]
BS T240 2 DOF Y/V = 0.237 [V]
BS T240 2 DOF Z/W = 0.231 [V]
BS T240 3 DOF X/U = 0.134 [V]
BS T240 3 DOF Y/V = 0.087 [V]
BS T240 3 DOF Z/W = 0.024 [V]
 

 


 

Jim W suggested that I run the script for the STS's as well while I'm here.

There are 1 STS proof masses out of range ( > 2.0 [V] )!
STS C DOF Z/W = 3.155 [V]


All other proof masses are within range ( < 2.0 [V] ):
STS A DOF X/U = -0.947 [V]
STS A DOF Y/V = 0.13 [V]
STS A DOF Z/W = -0.068 [V]
STS B DOF X/U = 0.886 [V]
STS B DOF Y/V = 0.62 [V]
STS B DOF Z/W = 0.563 [V]
STS C DOF X/U = -1.536 [V]
STS C DOF Y/V = -0.929 [V]
STS EX DOF X/U = 0.516 [V]
STS EX DOF Y/V = -1.076 [V]
STS EX DOF Z/W = 0.387 [V]
STS EY DOF X/U = 0.518 [V]
STS EY DOF Y/V = 0.683 [V]
STS EY DOF Z/W = -0.266 [V]

 


 

FAMIS #4366  closed
 

Displaying report 1-1 of 1.