Updated TCS simulation absorption coefficients and power scaling

[Aidan, Cao]

In the online TCS simulation, I updated the absorption coefficients for ITMX, ETMX and ETMY to reflect actual measured values: https://dcc.ligo.org/LIGO-T1400685

 

Additionally, I rescaled the TR_X and TR_Y values to reflect the arm powers, courtesy of some calibration work from Cao.

I have a script (copied below) I've been using to update these values as this allows me to store references to measurements and calibrations.

load_IFO_SIM_COEFFICIENTS.sh

#!/bin/bash
 
caput H1:TCS-SIM_IFO_XARM_LENGTH 3994.47   # aLOG 20149
caput H1:TCS-SIM_IFO_YARM_LENGTH 3994.47
caput H1:TCS-SIM_IFO_SILICA_REF_INDEX 1.44963  #Suprasil 3001, "Heraeus reports 1.44963 as the index at 1064", GLB email Sept 5, 2014
caput H1:TCS-SIM_XARM_POWER_WATTS_PER_INPUT_UNIT 2.606  # estimate of peak value of 105.9kW in arms (needs ref) between 1141200000 and 1141300000 coupled with measurements of TR_X
caput H1:TCS-SIM_YARM_POWER_WATTS_PER_INPUT_UNIT 2.378
 
caput H1:TCS-SIM_IFO_cdsMuxMatrix1_1_1 0.5
caput H1:TCS-SIM_IFO_cdsMuxMatrix1_1_2 0.5
caput H1:TCS-SIM_IFO_cdsMuxMatrix1_2_1 1.0
caput H1:TCS-SIM_IFO_cdsMuxMatrix1_2_2 -1.0
 
# PRC BLOCK
caput H1:TCS-SIM_IFO_PRC_ITM_R3 24.3931    #T0900043-v11, Table 1
caput H1:TCS-SIM_IFO_PRC_R3_R2 16.1558
caput H1:TCS-SIM_IFO_PRC_R2_RM 16.6037
 
caput H1:TCS-SIM_IFO_PRC_R3_ROC 36.021  # https://galaxy.ligo.caltech.edu/optics/  PR3-01
caput H1:TCS-SIM_IFO_PRC_R2_ROC -4.543 # https://galaxy.ligo.caltech.edu/optics/ PR2-04
caput H1:TCS-SIM_IFO_PRC_RM_ROC -10.948  # https://galaxy.ligo.caltech.edu/optics/ PRM-04
 
# SRC BLOCK
caput H1:TCS-SIM_IFO_SRC_ITM_R3 24.1176    #T0900043-v11, Table 1
caput H1:TCS-SIM_IFO_SRC_R3_R2 15.4607
caput H1:TCS-SIM_IFO_SRC_R2_RM 15.726#!/bin/bash#!/bin/bash

 

caput H1:TCS-SIM_IFO_XARM_LENGTH 3994.47   # aLOG 20149

caput H1:TCS-SIM_IFO_YARM_LENGTH 3994.47

caput H1:TCS-SIM_IFO_SILICA_REF_INDEX 1.44963  #Suprasil 3001, "Heraeus reports 1.44963 as the index at 1064", GLB email Sept 5, 2014

caput H1:TCS-SIM_XARM_POWER_WATTS_PER_INPUT_UNIT 2.606  # estimate of peak value of 105.9kW in arms (needs ref) between 1141200000 and 1141300000 coupled with measurements of TR

_X

caput H1:TCS-SIM_YARM_POWER_WATTS_PER_INPUT_UNIT 2.378

 

caput H1:TCS-SIM_IFO_cdsMuxMatrix1_1_1 0.5

caput H1:TCS-SIM_IFO_cdsMuxMatrix1_1_2 0.5

caput H1:TCS-SIM_IFO_cdsMuxMatrix1_2_1 1.0

caput H1:TCS-SIM_IFO_cdsMuxMatrix1_2_2 -1.0

 

# PRC BLOCK

caput H1:TCS-SIM_IFO_PRC_ITM_R3 24.3931    #T0900043-v11, Table 1

caput H1:TCS-SIM_IFO_PRC_R3_R2 16.1558

caput H1:TCS-SIM_IFO_PRC_R2_RM 16.6037

 

caput H1:TCS-SIM_IFO_PRC_R3_ROC 36.021  # https://galaxy.ligo.caltech.edu/optics/  PR3-01

caput H1:TCS-SIM_IFO_PRC_R2_ROC -4.543 # https://galaxy.ligo.caltech.edu/optics/ PR2-04

caput H1:TCS-SIM_IFO_PRC_RM_ROC -10.948  # https://galaxy.ligo.caltech.edu/optics/ PRM-04

 

# SRC BLOCK

caput H1:TCS-SIM_IFO_SRC_ITM_R3 24.1176    #T0900043-v11, Table 1

caput H1:TCS-SIM_IFO_SRC_R3_R2 15.4607

caput H1:TCS-SIM_IFO_SRC_R2_RM 15.726

 

caput H1:TCS-SIM_IFO_SRC_R3_ROC 36.013  # https://galaxy.ligo.caltech.edu/optics/  SR3-02

caput H1:TCS-SIM_IFO_SRC_R2_ROC -6.424 # https://galaxy.ligo.caltech.edu/optics/ SR2-04

caput H1:TCS-SIM_IFO_SRC_RM_ROC -5.638  # https://galaxy.ligo.caltech.edu/optics/ SRM-05 ????? - CHECK

 

# SPRING CONSTANTS

caput H1:TCS-SIM_IFO_YARM_PEND_SPR_CNST 1.0  # ??????

caput H1:TCS-SIM_IFO_XARM_PEND_SPR_CNST 1.0  # ??????

 

# ACOS PRC BLOCK

caput H1:TCS-SIM_IFO_ACOS_PRC_A_D_OFFSET 0.87

caput H1:TCS-SIM_IFO_ACOS_PRC_A_D_A0 0.5155940062460905

caput H1:TCS-SIM_IFO_ACOS_PRC_A_D_A1 -2.0281847857870914

caput H1:TCS-SIM_IFO_ACOS_PRC_A_D_A2 -3.6292076586482307

caput H1:TCS-SIM_IFO_ACOS_PRC_A_D_A3 -14.378615634122346

caput H1:TCS-SIM_IFO_ACOS_PRC_A_D_A4 -69.29856186065047

caput H1:TCS-SIM_IFO_ACOS_PRC_A_D_A5 -373.821577053177

 

# ACOS SRC BLOCK

caput H1:TCS-SIM_IFO_ACOS_SRC_A_D_OFFSET 0.87

caput H1:TCS-SIM_IFO_ACOS_SRC_A_D_A0 0.5155940062460905

caput H1:TCS-SIM_IFO_ACOS_SRC_A_D_A1 -2.0281847857870914

caput H1:TCS-SIM_IFO_ACOS_SRC_A_D_A2 -3.6292076586482307

caput H1:TCS-SIM_IFO_ACOS_SRC_A_D_A3 -14.378615634122346

caput H1:TCS-SIM_IFO_ACOS_SRC_A_D_A4 -69.29856186065047

caput H1:TCS-SIM_IFO_ACOS_SRC_A_D_A5 -373.821577053177

 

# ACOS YARM BLOCK

caput H1:TCS-SIM_IFO_ACOS_XARM_SQRT_G_OFFSET 0.87

caput H1:TCS-SIM_IFO_ACOS_XARM_SQRT_G_A0 0.5155940062460905

caput H1:TCS-SIM_IFO_ACOS_XARM_SQRT_G_A1 -2.0281847857870914

caput H1:TCS-SIM_IFO_ACOS_XARM_SQRT_G_A2 -3.6292076586482307

caput H1:TCS-SIM_IFO_ACOS_XARM_SQRT_G_A3 -14.378615634122346

caput H1:TCS-SIM_IFO_ACOS_XARM_SQRT_G_A4 -69.29856186065047

caput H1:TCS-SIM_IFO_ACOS_XARM_SQRT_G_A5 -373.821577053177

 

 

# ACOS XARM BLOCK

caput H1:TCS-SIM_IFO_ACOS_YARM_SQRT_G_OFFSET 0.87

caput H1:TCS-SIM_IFO_ACOS_YARM_SQRT_G_A0 0.5155940062460905

caput H1:TCS-SIM_IFO_ACOS_YARM_SQRT_G_A1 -2.0281847857870914

caput H1:TCS-SIM_IFO_ACOS_YARM_SQRT_G_A2 -3.6292076586482307

caput H1:TCS-SIM_IFO_ACOS_YARM_SQRT_G_A3 -14.378615634122346

caput H1:TCS-SIM_IFO_ACOS_YARM_SQRT_G_A4 -69.29856186065047

caput H1:TCS-SIM_IFO_ACOS_YARM_SQRT_G_A5 -373.821577053177

 

# OPTICS gains

caput H1:TCS-SIM_ITMX_SUB_DEFOCUS_RH_GAIN -9.0E-6

caput H1:TCS-SIM_ITMY_SUB_DEFOCUS_RH_GAIN -9.0E-6

caput H1:TCS-SIM_ETMX_SUB_DEFOCUS_RH_GAIN -9.0E-6

caput H1:TCS-SIM_ETMY_SUB_DEFOCUS_RH_GAIN -9.0E-6

 

caput H1:TCS-SIM_ITMX_SUB_DEFOCUS_CO2_GAIN 62.3E-6

caput H1:TCS-SIM_ITMY_SUB_DEFOCUS_CO2_GAIN 62.3E-6

 

caput H1:TCS-SIM_ITMX_SUB_DEFOCUS_SELF_GAIN 4.8709E-4

caput H1:TCS-SIM_ITMY_SUB_DEFOCUS_SELF_GAIN 4.8709E-4

caput H1:TCS-SIM_ETMX_SUB_DEFOCUS_SELF_GAIN 3.8577E-4

caput H1:TCS-SIM_ETMY_SUB_DEFOCUS_SELF_GAIN 3.8577E-4

 

caput H1:TCS-SIM_ITMX_SURF_DEFOCUS_RH_GAIN 1.066E-6

caput H1:TCS-SIM_ITMY_SURF_DEFOCUS_RH_GAIN 1.066E-6

caput H1:TCS-SIM_ETMX_SURF_DEFOCUS_RH_GAIN 1.066E-6

caput H1:TCS-SIM_ETMY_SURF_DEFOCUS_RH_GAIN 1.066E-6

 

caput H1:TCS-SIM_ITMX_SURF_DEFOCUS_SELF_GAIN -3.652E-5

caput H1:TCS-SIM_ITMY_SURF_DEFOCUS_SELF_GAIN -3.652E-5

caput H1:TCS-SIM_ETMX_SURF_DEFOCUS_SELF_GAIN -2.931E-5

caput H1:TCS-SIM_ETMY_SURF_DEFOCUS_SELF_GAIN -2.931E-5

 

caput H1:TCS-SIM_ITMX_SURF_ROC_NOM 1939.3

caput H1:TCS-SIM_ITMY_SURF_ROC_NOM 1939.2

caput H1:TCS-SIM_ETMX_SURF_ROC_NOM 2241.54

caput H1:TCS-SIM_ETMY_SURF_ROC_NOM 2238.9

caput H1:TCS-SIM_ITMX_SUB_DEFOCUS_STATIC -1.2467E-5

caput H1:TCS-SIM_ITMY_SUB_DEFOCUS_STATIC 1.7479E-6

 

caput H1:TCS-SIM_ITMX_SURF_ABSORPTION 520E-9  # alog 16578

caput H1:TCS-SIM_ITMY_SURF_ABSORPTION 250E-9

caput H1:TCS-SIM_ETMX_SURF_ABSORPTION 160E-9 # aLOG 19867