Displaying report 1-1 of 1.
Reports until 22:38, Friday 11 March 2016
H1 ISC
stefan.ballmer@LIGO.ORG - posted 22:38, Friday 11 March 2016 - last comment - 22:43, Friday 11 March 2016(26036)
Violin modes rung up

We are daming them overnight, sitting at 5W. Also wrote the adjustDamperGain script below. It measures the peak count output of a fliter module, and scales the gain to set a target peak level. (Or the maximal allowable gain.)

We left the guardian script calling this function for the modes that were problematic toinight:

ISC_LOCK.py, line 2362

        # the following violins were saturating on March 11 2016 with above gains - turn them down
        time.sleep(10)
        adjustDamperGain('SUS-ETMY_L2_DAMP_MODE5',-100,1.5e5)
        adjustDamperGain('SUS-ETMX_L2_DAMP_MODE6',100,1.5e5)
        adjustDamperGain('SUS-ITMY_L2_DAMP_MODE3',100,1.5e5)
 

def adjustDamperGain(FM,maxgain,targetCounts):
    """read the FM output and scale the gain to match targetCOunts"""
    dmax=numpy.max(numpy.abs(cdsutils.getdata(FM+'_OUTPUT',1).data))
    oldgain=ezca[FM+'_GAIN']
    newgain=oldgain*targetCounts/dmax
    if (abs(newgain/maxgain)<1.0):
        ezca[FM+'_GAIN'] = newgain
    else:
        ezca[FM+'_GAIN'] = maxgain
    
 

Comments related to this report
robert.ward@LIGO.ORG - 22:43, Friday 11 March 2016 (26037)

We took a fine-resolution, high-frequency spectrum using the IOP channels of the DCPD outputs in this state, to try to identify the harmonics of the violin modes so we know them for posterity.  The dtt files are in /ligo/home/robert.ward/Documents/ExcitedViolinModes/

Displaying report 1-1 of 1.