Displaying report 1-1 of 1.
Reports until 17:21, Wednesday 16 March 2016
H1 ISC (ISC)
hang.yu@LIGO.ORG - posted 17:21, Wednesday 16 March 2016 - last comment - 18:21, Wednesday 16 March 2016(26105)
calibrated sensing matrix at 2.1 W

Sheila, Hang

AS port:

AS_A_36
  BS SRM SRC2 DC3 DC4 CSOFT CHARD DSOFT DHARD PRM PR3 INP1
Transfer Function, [W/rad] 7.56e+2 1.19e+1 4.02e+1 2.09e+2 0 3.37e+1 2.64e+1 2.50e+2 2.04e+2 1.38e-2 3.13e+1 5.92e-3
Demod phase, [deg] -67 30 43 52 N/A -155 24 111 -62 -108 17 -73
Noise floor, [rad/Hz^{1/2}] 5.4e-13 3.4e-11 1.0e-11 1.96e-12 inf 1.2e-11 1.6e-11 1.6e-12 2.0e-12 3.0e-8 1.3e-11 6.9e-8

 

AS_B_36
  BS SRM SRC2 DC3 DC4 CSOFT CHARD DSOFT DHARD PRM PR3 INP1
Transfer Function, [W/rad] 6.94e+2 3.24e+1 3.58e+1 9.15e-1 2.12e+2 5.44e+1 4.52e+1 2.32e+2 1.85e+2 1.7e-2 5.65e+1 4.43e-3
Demod phase, [deg] -91 -168 25 -40 3 -8 172 88 -100 49 -170 116
Noise floor, [rad/Hz^{1/2}] 8.1e-13 1.74e-11 1.6e-11 6.2e-10 2.7e-12 1.0e-11 1.2e-11 2.4e-12 3.1e-12 3.3e-8 1.0e-11 1.3e-7

 

AS_A_45
  BS SRM SRC2 DC3 DC4 CSOFT CHARD DSOFT DHARD PRM PR3 INP1
Transfer Function, [W/rad] 2.01e+2 2.83e+1 4.34e+1 1.80e+2 1.28e+0 1.83e+2 2.47e+2 1.58e+2 2.78e+3 1.66e-3 4.76e+0 1.38e-3
Demod phase, [deg] -48 -86 -92 -91 92 45 44 -115 -87 133 -26 63
Noise floor, [rad/Hz^{1/2}] 3.4e-13 2.4e-12 1.5e-12 3.7e-13 5.2e-11 3.7e-13 2.7e-13 4.24e-13 2.4e-14 3.9e-8 1.4e-11 4.9e-8

 

AS_B_45
  BS SRM SRC2 DC3 DC4 CSOFT CHARD DSOFT DHARD PRM PR3 INP1
Transfer Function, [W/rad] 1.43e+2 3.75e+1 2.00e+1 8.57e+0 1.52e+2 2.29e+2 2.92e+2 1.55e+2 2.53e+3 2.00e-3 1.37e+1 1.85e-3
Demod phase, [deg] 132 87 -104 86 -91 -111 -113 71 87 -62 112 -108
Noise floor, [rad/Hz^{1/2}] 3.7e-13 1.4e-12 2.6e-12 6.0e-12 3.4e-13 2.2e-13 1.8e-13 3.3e-13 2.0e-14 2.6e-8 3.7e-12 2.8e-8

 

AS_A_DC
  BS SRM SRC2 DC3 DC4 CSOFT CHARD DSOFT DHARD PRM PR3 INP1
Transfer Function, [W/rad] -9.8e+1 -2.1e+1 -3.1e+1 -1.3e+2 0 4.4e+1 3.5e+1 -4.8e+1 -9.8e+2 0 1.7e+0 5.2e-4
Noise floor, [rad/Hz^{1/2}] 2.2e-12 1.0e-11 7.1e-12 1.7e-12 inf 5.0e-12 6.3e-12 4.6e-12 2.2e-13 inf 1.3e-10 4.2e-7

 

AS_B_DC
  BS SRM SRC2 DC3 DC4 CSOFT CHARD DSOFT DHARD PRM PR3 INP1
Transfer Function, [W/rad] 4.9e+1 2.3e+1 -1.3e+1 2.2e0 -1.0e2 -4.5e+1 0 3.6e+1 7.3e+2 -2.5e-3 1.2e+1 1.6e-3
Noise floor, [rad/Hz^{1/2}] 5.7e-12 1.2e-11 2.2e-11 1.3e-10 2.8e-12 6.2e-12 inf 7.8e-12 3.8e-13 1.1e-7 2.3e-11 1.8e-7

 

 

AS_A_RF90
  BS SRM SRC2 DC3 DC4 CSOFT CHARD DSOFT DHARD PRM PR3 INP1
Transfer Function, [W/rad] 4.9e+1 0 0 -2.2e0 0 0 0 0 0 0 1.0e+0 0
Noise floor, [rad/Hz^{1/2}] 3.3e-11 inf inf 7.4e-10 inf inf inf inf inf inf 1.6e-9 inf

 

AS_B_RF90
  BS SRM SRC2 DC3 DC4 CSOFT CHARD DSOFT DHARD PRM PR3 INP1
Transfer Function, [W/rad] 0 1.5e+0 0 0 -6.7e+0 0 0 0 0 0 3.6e-1 0
Noise floor, [rad/Hz^{1/2}] inf 8.6e-10 inf inf 1.9e-10 inf inf inf inf inf 3.6e-9 inf

 

AS_C
  BS SRM SRC2 DC3 DC4 CSOFT CHARD DSOFT DHARD PRM PR3 INP1
Transfer Function, [W/rad] 2.1e+1 8.8e+0 -1.6e+1 6.3e-1 0 -1.1e+1 1.9e+1 5.7e+0 1.7e+2 -1.5e-3 8.3e+0 8.1e-4
Noise floor, [rad/Hz^{1/2}] 2.6e-12 6.3e-12 3.5e-11 8.8e-11 inf 5.0e-12 2.9e-12 9.7e-12 3.2e-13 3.7e-8 6.7e-12 6.8e-8
Comments related to this report
hang.yu@LIGO.ORG - 18:21, Wednesday 16 March 2016 (26108)ISC

At REFL port:

REFL_A_RF45
  BS SRM SRC2 DC3 DC4 CSOFT CHARD DSOFT DHARD PRM PR3 INP1
[W/rad] 1.5e+2 7.5e+0 2.7e+1 0 0 0 4.1e+2 0 0 3.8e-2 2.4e+1 4.9e-1
[deg] -137 -9 172       13     174 21 -169
[rad/Hz^{1/2}] 2.4e-12 4.9e-11 1.4e-11 inf inf inf 9.0e-13 inf inf 9.7e-9 1.5e-11 7.5e-10

 

REFL_B_RF45
  BS SRM SRC2 DC3 DC4 CSOFT CHARD DSOFT DHARD PRM PR3 INP1
resp [W/rad] 1.3e+2 9.0e+0 2.3e+1 0 0 1.2e+1 4.1e+2 2.0e+1 0 2.8e-2 4.7e+1 4.2e-1
dmd phase [deg] -129 -122 54     -37 19 -138   37 25 20
noise [rad/Hz^{1/2}] 2.8e-12 4.1e-11 1.6e-11 inf inf 3.1e-11 8.9e-13 1.8e-11 inf 1.3e-8 7.8e-12 8.7e-10

 

REFL_A_RF9
  BS SRM SRC2 DC3 DC4 CSOFT CHARD DSOFT DHARD PRM PR3 INP1
resp [W/rad] 6.8e+1 0 0 0 0 3.2e+1 4.0e+2 0 0 0 2.4e+1 5.8e-1
dmd phase [deg] 2         10 16       175 -169
noise [rad/Hz^{1/2}] 4.6e-12 inf inf inf inf 9.7e-12 7.8e-13 inf inf inf 1.3e-11 5.3e-10

 

REFL_B_RF9
  BS SRM SRC2 DC3 DC4 CSOFT CHARD DSOFT DHARD PRM PR3 INP1
resp [W/rad] 7.8e+1 0 0 0 0 6.4e+1 3.6e+2 0 0 2.9e-2 6.4e+1 4.5e-1
dmd phase [deg] 12         10 169     13 -169 15
noise [rad/Hz^{1/2}] 3.4e-12 inf inf inf inf 4.2e-12 7.4e-13 inf inf 9.2e-9 4.2e-12 6.0e-10

 

REFL_A_DC
  BS SRM SRC2 DC3 DC4 CSOFT CHARD DSOFT DHARD PRM PR3 INP1
resp [W/rad] 0 0 0 0 0 0 0 0 0 0 5.3e-1 -3.5e-3
noise [rad/Hz^{1/2}] inf inf inf inf inf inf inf inf inf inf 6.5e-10 9.8e-8

 

REFL_B_DC
  BS SRM SRC2 DC3 DC4 CSOFT CHARD DSOFT DHARD PRM PR3 INP1
resp [W/rad] 0 0 0 0 0 0 0 0 0 0 -2.6e-1 -1.6e-3
noise [rad/Hz^{1/2}] inf inf inf inf inf inf inf inf inf inf 9.1e-10 1.5e-7

 

TR (calibration of the pd may be quite off, but the noise floor in rad/sqrt{Hz} should be accurate):

X_TR_A
  BS SRM SRC2 DC3 DC4 CSOFT CHARD DSOFT DHARD PRM PR3 INP1
resp [W???/rad] 0 -8.1e-3 0 0 0 0 -1.75e+1 0 -1.72e+1 -1.7e-5 5.2e-2 0
noise [rad/Hz^{1/2}] inf 5e-10 inf inf inf inf 2.3e-13 inf 2.3e-13 2.4e-7 7.7e-11 inf

 

X_TR_B
  BS SRM SRC2 DC3 DC4 CSOFT CHARD DSOFT DHARD PRM PR3 INP1
resp [W???/rad] 0 -9.2e-3 0 0 0 -8.4e-1 -2.1e+1 -9.9e-1 2.1e+1 -1.36e-5 6.0e-2 0
noise [rad/Hz^{1/2}] inf 3.6e-10 inf inf inf 3.9e-12 1.6e-13 3.3e-12 1.6e-13 2.4e-7 5.5e-11 inf

 

Y_TR_A
  BS SRM SRC2 DC3 DC4 CSOFT CHARD DSOFT DHARD PRM PR3 INP1
resp [W???/rad] 0 2.1e-2 3.5e-2 0 0 -1.6e+0 -2.1e+1 1.4e+0 -2.1e+1 0 7.2e-2 0
noise [rad/Hz^{1/2}] inf 1.6e-10 inf inf inf 2.1e-12 1.6e-13 2.4e-12 1.6e-13 inf 4.6e-11 inf

 

Y_TR_B
  BS SRM SRC2 DC3 DC4 CSOFT CHARD DSOFT DHARD PRM PR3 INP1
resp [W???/rad] 8.7e-2 1.6e-2 1.9e-2 0 0 3.7e+0 -3.7e+0 3.5e+0 4.0e+0 0 2.1e-2 0
noise [rad/Hz^{1/2}] 4.1e-11 2.25e-10 1.9e-10 inf inf 9.7e-13 9.7e-13 1.0e-12 9.0e-13 inf 1.7e-10 inf
Displaying report 1-1 of 1.